Notes on preparing insulated wire samples for test
The object of the test is to ensure the connection is a good Electro-mechanical joint. Bucketed termination barrel should not grip the insulation. Clear ALL Insulation from the wire near the crimp to ensure compliance.

MANUAL HT1 LEVER 700N Max. |

MANUAL TCW-5 1000N Max. |

MANUAL TCR12 10KN Max |

MOTOR FDT100 1000N Max |

MOTOR FDT202 2500N Max |

TYPICAL CRIMP TEST FIXTURES |
TYPICAL CRIMP PULL-OFF FORCE @25-50mm/min.
| CONDUCTOR SIZE |
MINIMUM PULL-OFF |
| CSA mm2 |
Strands/CSA |
| 0.22 |
7/0.2 |
| 0,50 |
16/0.2 |
| 0.75 |
24/0.2 |
| 1.00 |
32/0.2 |
| 1.50 |
30/0.25 |
| 2.50 |
50/0.25 |
| 4.00 |
7/0.85 |
| 6.00 |
84/0.3 |
| 10.00 |
84/0.4 | |
| Kg |
NEWTONS |
| 3.0 |
30 |
| 7,0 |
70 |
| 10.0 |
100 |
| 14.0 |
140 |
| 21.0 |
210 |
| 28.0 |
280 |
| 21.0 |
510 |
| 60.0 |
600 |
| 100.0 |
1000 | | Pull-Off force may vary with customer requirements
|